On This Page
System
Overview
Wiring
Requirements
CAT
Cable Pin-Out
Recommended
Cable Distances
GP002
Field-Terminated Installations
GC005
Plug-and-Play Installations
Related
Guides
System Overview
Gantom GC-series fixtures and accessories use CAT5e or
higher cable with RJ45 connectors to carry:
Low-voltage
power
DMX
control data
Important:
Wiring Requirements
(NOTE: Improper wiring may cause damage)
CAT Cable Pin-Out
|
Function
|
CAT Conductors
|
|
V+
|
Blue, White/Blue, White/Green
|
|
GND
|
Green, Brown, White/Brown
|
|
DMX−
|
Orange
|
|
DMX+
|
White/Orange
|
(see attached pin-out guide)
Recommended Cable Distances
|
Supply Voltage
|
Recommended Maximum Distance
|
|
12V DC
|
~75 ft (23 m)
|
|
24V DC
|
~300 ft (91 m)
|
Actual distance may vary depending on fixture load and cable
quality.
GP002 Field-Terminated Installations
The GP002 G8 Distribution Box supports field-terminated CAT
cable installations using Phoenix push-terminal connections.
See:
GC005 Plug-and-Play Installations
The GC005 provides:
See: